Calibration Of Thermo-couples and Thermometer

Calibration Of Thermo-couples and Thermometer

Calibration Of Thermo-couples and Thermometer The set up consists of constant temperature Bath with heating element. This Heat source is controlled with the help of digital temp controlleratany preset valve. A thermo-couple pocket is provided to insert the thermo-couple in it. Three thermo-couples i.e. CR/AL, Cu-constantan ,Fe-constantan and Digital mili volt meter are also provided … Continue reading “Calibration Of Thermo-couples and Thermometer”





Control Valve Characteristics

Control Valve Characteristics

Control Valve Characteristics The setup is designed to understand the control valve operation and its flow characteristics. It consists of pneumatic control valves of linear, equal% (& quick opening for product 318B) type, stainless steel water tank with pump for continuous water circulation and rotameter for flow measurement. An arrangement is made to measure pressure … Continue reading “Control Valve Characteristics”





Dead Weight Pressure Gauge Tester

Dead Weight Pressure Gauge Tester

Dead Weight Pressure Gauge Tester DESCRIPTION: The present set-up is designed to calliberate and check the given pressure gauge (Bourdon Type). This unit consists of a precision ground plunger, which develops the required pressure by loading of weights.This pressure is transmitted to the pressure gauge by oil. TECHNICAL DETAILS: Precision ground plunger to develop the … Continue reading “Dead Weight Pressure Gauge Tester”





Interaction And Non-Interacting System

Interaction And Non-Interacting System

Interaction And Non-Interacting System Description: The setup studies behavior of multi capacity process when connected in non interaction mode. It consists of supply tank, pump for water circulation, Rotameter for flow measurement, two independent process tanks with scales connected in non-interacting mode. The components are assembled on frame to form tabletop set-up. TECHNICAL SPECIFICATION: Process … Continue reading “Interaction And Non-Interacting System”





Level Control Trainer

Level Control Trainer

Level Control Trainer DESCRIPTION : The setup consists of a process tank fitted with scale in which water enters through a Pneumatic control valve. Water is pumped to process tank from the sump tank by means of a centrifugal pump. The level transmitter is fitted in the process tank. The level of water in process … Continue reading “Level Control Trainer”





Measurement Of Level By Air Purge Method

Measurement Of Level By Air Purge Method

Measurement Of Level By Air Purge Method DESCRIPTION :- The apparatus is based on the principle that when compressed air is purged into the pipe, the liquid within the pipe is displaced by air pressure equal to the hydro-static force of the liquid in the tank or vessel. The apparatus consists of a pipe lowered … Continue reading “Measurement Of Level By Air Purge Method”





Measurement Of Level By Capacitance Method

Measurement Of Level By Capacitance Method

Measurement Of Level By Capacitance Method Technical Description: The present set-up is designed to study the working principle and calibration procedure of capacitance type level transmitter. The set-up consists of a pro be which is mounted in a level tank with graduated scale. Water is poured in the level tank manually and response of the … Continue reading “Measurement Of Level By Capacitance Method”





Pneumatic Tiainer

Pneumatic Tiainer

Pneumatic Trainer Pneumatic Trainer Advanced Hydraulic Trainer outlines the basic Principle of Hydraulic Control System, Hydraulic Control System Components & amp; its applications. Along with components of Basic Hydraulic Trainer, it consists of additional components like Hydraulic Accumulator, Hydraulic Motor etc. It elaborates different types of Hydraulic Circuits such as Meter-in Circuit, Meter-out Circuit, Bleed-off … Continue reading “Pneumatic Tiainer”





Pressure Control Unit

Pressure Control Unit

Pressure Control Unit Description Pressure control trainer is designed for understanding the basic principles of pressure control. The process set up consists of pressure vessel fitted with pneumatic control valve. Pressure transmitter is used for pressure sensing. The process parameter (Pressure) is controlled by microprocessor based digital indicating controller which manipulates pneumatic control valve fitted … Continue reading “Pressure Control Unit”





Single Tank System

Single Tank System

Technical Description: The setup studies behavior of single tank system. It consists of supply tank, pump for water circulation, Rota meter for flow measurement, one process tanks with scale. The components are assembled on frame to form tabletop models.  TECHNICAL SPECIFICATION: Process Tank: Material Stainless Steel, Circular, with graduated level scale ( 2 Nos.) capacity … Continue reading “Single Tank System”





Temperature Control Trainer

Temperature Control Trainer

Temperature Control Trainer Description This teaching and training system provides a comprehensive experimental introduction to the fundamentals of process control using an example of temperature control.  A circulating pump transfers water within a closed circuit. The flow of water can be regulated by a hand-operated valve. The loop also contains a screw-in heater, a heat exchanger with fan, … Continue reading “Temperature Control Trainer”





Time Constant Of Manometer

Time Constant Of Manometer

Time Constant Of Manometer TECHNICAL DESCRIPTION : Three Different lengths of manometer are selected & used to measure the manometer difference. An air filter regulator is used to provide air at constant pressure. DIMENSIONS AND WEIGHT : Size : 0.7 m.(L) x 0.5m(W) x 1.2m ( H ) Weight : Approx. 2 Kg





Time Constant Of Thermocouples & Thermometer

Time Constant Of Thermocouples & Thermometer

Technical Description: The setup consists of a Heat source controlled with the help of digital temperature controller at any preset value. A thermometer/thermo-couple pocket is provided to insert the thermometer/thermo-couple in it. The time constant of different thermometer/thermo-couple can be calculated with the set-up. A stopwatch is also provided for measurement of time. A Heat sink is … Continue reading “Time Constant Of Thermocouples & Thermometer”





Two Tank Interacting System

Two Tank Interacting System

Two Tank Interacting System TECHNICAL DESCRIPTION: The setup studies behavior of multi capacity process when connected in interaction mode. It consists of supply tank, pump for water circulation, Rotameter for flow measurement, two independent process tanks with scales connected in interacting mode. The components are assembled on frame to form tabletop set-up. TECHNICAL SPECIFICATION: Process … Continue reading “Two Tank Interacting System”





Two Tank Non-Interacting System

Two Tank Non-Interacting System

Two Tank Non-Interacting System TECHNICAL DESCRIPTION: The setup studies behavior of multi capacity process when connected in non-interaction mode. It consists of supply tank, pump for water circulation, Rota-meter for flow measurement, two independent process tanks with scales connected in interacting mode. The components are assembled on frame to form tabletop set-up. TECHNICAL SPECIFICATION: Process … Continue reading “Two Tank Non-Interacting System”