E/M Apparatus & Valve Experiments
Showing all 7 results
Diode Valve Characteristics Apparatus
Diode Valve Characteristics Apparatus Features: Instrument comprises of DC Regulated Power Supply 0-250VDC/30mA, Variable AC Power Supply 6.3 VAC/1Amp, two round meters for voltage & current measurement.
E/M By Helical’s Method
E/M By Helical’s Method Features : Kit Comprises of High Voltage Power Supply Unit with intensity, focus X, Y, deflection & Solenoid current controls. Two metes are provided in Power Supply for Acceleration Voltage control & for solenoid current controls. One Solenoid Unit Comprises of one Solenoid mounted on Wooden stand & CRT is kept … Continue reading “E/M By Helical’s Method”
E/M By Milikan’s Oil Drop Method
E/M By Milikan’s Oil Drop Method Millikans oil Drop Apparatus is used to measure the Elementary Electric Charge. To achieve this, tiny charged droplets of oil are finely sprayed into two metal electrodes placed horizontally. Heavier drops tend to fall downwards fastly due to their thermal velocity but the lighter ones remain almost steady inside … Continue reading “E/M By Milikan’s Oil Drop Method”
Ionization Potential Of Mercury Using Thyratron Valve
Ionization Potential Of Mercury Using Thyratron Valve Features:- Instrument comprises of DC regulated power supply 0-15VDC/150mA & AC power supply 6.3 VAC/1Amp, two round meters for voltage & current measurement, valve diagram is printed on front panel, connection of supplies and valve brought out at 4mm sockets.
Tetrode/ Pentode Valve Characteristics Apparatus
Tetrode/ Pentode Valve Characteristics Apparatus Features : Instrument comprises of Two DC Regulated Power Supplies 0-300VDC/30mA & One 0-15 VDC/10mA, AC Power Supply 6.3 VAC/1Amp, four round meters for voltage & Current measurement, valve diagram is Printed on Front panel, connections of Supplies & Valve brought out at 4mm Socket/Terminals.
Triode Valve Characteristics Apparatus
Triode Valve Characteristics Apparatus Features : Instrument comprises of DC Regulated Power Supply 0-300VDC/ 30mA & 0-25VDC/10mA, AC Power Supply 6.3 VAC/1Amp, two round meters for voltages & current measurement, valve diagram is printed on front panel, connections of supplies & valve brought out at 4mm socket.
Work Function Of Diode (Richardson Law)
Work Function Of Diode (Richardson Law) Features : Instrument comprises of DC Regulated power supply of 0-6 V & 0-300 V. Two volt meters & two current meters are mounted on the front panel. Valve diagram is printed on the panel & connection are brought out on sockets/terminals.