Two Tank Non-Interacting System
Two Tank Non-Interacting System
TECHNICAL DESCRIPTION:
The setup studies behavior of multi capacity process when connected in non-interaction mode. It consists of supply tank, pump for water circulation, Rota-meter for flow measurement, two independent process tanks with scales connected in interacting mode. The components are assembled on frame to form tabletop set-up.
TECHNICAL SPECIFICATION:
Process Tank: Material Stainless Steel, Circular, with graduated level scale ( 2 Nos.) capacity 2.5 to 3.5 liters.
Supply Tank: Material Stainless Steel, Capacity 20 liters.
Overhead tank: Material Stainless Steel, Capacity 5 liters.
Water Circulation: FHP Pump, Tullu/Standard make.
Piping: SS/PVC, size ¼
Flow Measurement: Rota-meter.