Engineering Equipment
Showing 273–288 of 586 results
Linear System Simulator
Linear System Simulator Experiments: Open and closed loop step response of First Order type-0 system for various values of gain Open and closed loop step response of Second Order type-0 and type-1 systems Response of third order system Steady-State errors for closed loop configuration through triangular wave input. The number of experiments possible on the … Continue reading “Linear System Simulator”
Linear Wave Shaping Circuits
Linear Wave Shaping Circuits Features: Fixed DC Regulated power supply of 12V. Operational amplifier IC 741 is placed inside the cabinet and connections are brought out on sockets.Combination of resistor, capacitor, diodes are provided on the front panel.
Liquid-Liquid Extraction In A Packed Tower
Liquid-Liquid Extraction In A Packed Tower DESCRIPTION: The set-up consists of a glass column packed with Rasching rings. Continuous counter current contacts between the solvent and solute phases is made, which results into extract and raffinate streams. Flow meters (Rota-meters) are used to note the flow of solvent & solute respectively. The continuous and dispersed … Continue reading “Liquid-Liquid Extraction In A Packed Tower”
Load Test Of Dc Shunt Motor
Load Test Of Dc Shunt Motor Specifications: 1. DC Shunt motor With Loading Arrangement 1HP, 230V, DC & 1500 RPM. 2. Motor is copper wound with class b insulation. 3. It is supplied with one MS powder coated Electrical panel fitted with high insulation Bakelite sheet. 4. Analog ammeter and voltmeter are provided on the … Continue reading “Load Test Of Dc Shunt Motor”
Loading Effect Of Potentiometer
Loading Effect Of Potentiometer Specifications : Completely self contained standalone unit Demonstrates the principle and working of potentiometers and effect of loading Built-in two (2) different types of potentiometers, viz., Single turn Potentiometer with knob Built-in Resistive Load Bank (4 different Resistive Loads) for loading the potentiometers Built-in IC based DC regulated power supply with … Continue reading “Loading Effect Of Potentiometer”
Logic Controller Interface
Logic Controller Interface Logic Controller Interface is worldwide used for making multiple arrangements in digital as well as analog inputs and outputs for extending temperature range. Logic Controller Interface Card The logic controller interface provides the user with eight TTL buffered outputs and eight TTL buffered inputs. The logic state of each input and output is … Continue reading “Logic Controller Interface”
Losses Due To Friction In Pipe Line
Losses Due To Friction In Pipe Line Friction Pipe Lines Apparatus Sigma-:- The Set-up consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use … Continue reading “Losses Due To Friction In Pipe Line”
Losses In Pipe Fitting Apparatus
Losses In Pipe Fitting Apparatus- Engineering Equipment The unit provide study of losses of pipe in various pipe fitting. A unit consists of Major and minor losses associated with pipe flow in piping networks helps in determining the pumping power requirements, material and fittings selection. A good understanding of such losses helps engineers in designing … Continue reading “Losses In Pipe Fitting Apparatus”
LVDT (Linear Variable Differential Transformer) Trainer
LVDT (Linear Variable Differential Transformer) Trainer Description : Instrumentation trainer has been designed specifically for to study Linear Variable Differential Transducer (L.V.D.T.). The board is absolutely self contained & require no other apparatus. Practical experience on this set up carries great educative value for Science and Engineering Students.
M-Deriveed ‘T’ Type Passive Low Pass & High Pass Filters
M-Deriveed ‘T’ Type Passive Low Pass & High Pass Filters Features of the Trainer : Housing : It is mounted in an elegant ABS Plastic cabinet for better viewing and portability Weight : 1.5kgs This trainer is a glass-epoxy printed circuit board and all the symbols screen-printed on the front panel so that it enables the student … Continue reading “M-Deriveed ‘T’ Type Passive Low Pass & High Pass Filters”
Magnetic Amplifier
Magnetic Amplifier Technical Specifications Magnetic Amplifier : High gain, vacuum impregnated with twin storable reactors. Reactor : Storable, made of torroidal core. Core : Torroidal, cold rolled grain oriental core with low loss & high permeability. Windings : 1. Load (gate) windings wound dividually on each saturable eactors. 2. Control winding. 3. Bias winding. 4. … Continue reading “Magnetic Amplifier”
Magnetic Amplifier (Positive & Negative Feedback)
Magnetic Amplifier Trainer Positive & Negative Amplification is the control of a larger output quantity by the variation of a smaller input quantity. Such amplification can be performed by a magnetic device called Magnetic Amplifier or Magamp. This set up is designed to study the basic characteristics of such amplifier with +Ve & “Ve feedback. … Continue reading “Magnetic Amplifier (Positive & Negative Feedback)”
Magnetic Amplifier (Series & Parallel)
Magnetic Amplifier (Series & Parallel) Amplification is the control of a larger output quantity by the variation of a smaller input quantity. Such amplification can be performed by saturable reactors connected either in series or in parallel. This set up consists two such reactors, AC and DC power supply, two meters for load and control currents … Continue reading “Magnetic Amplifier (Series & Parallel)”
Magnetic Separator
Magnetic Separator Description: Materials, that have different magnetic at tractability, may be separated by passing them through a magnetic field. Most often, magnetic separation techniques are used to remove iron, steel or magnetic iron oxide from materials low in magnetic at tractability. These devices operate in either a continuous or a cyclic manner. Continuous devices … Continue reading “Magnetic Separator”
Mass Transfer With & Without Chemical Reaction (Solid -Liquid)
Mass Transfer With & Without Chemical Reaction (Solid -Liquid) Description: The setup consists of a Reactor, in which solid cylinder of Benzoic Acid is placed and is stirred by means of a variable speed mixer. Baffles are also provided. The Reactor is made of Stainless Steel. Peltilizer is provided to make the solid cylinder of … Continue reading “Mass Transfer With & Without Chemical Reaction (Solid -Liquid)”
Maximum Power Transfer Theorem
Maximum Power Transfer Theorem Specification : DC Regulated Power Supply of +12V.Variable resistance VR (potentiometer), is mounted on the front panel. Voltmeter and current meters are mounted on front panel to measure the voltage & current. Three type of resistance R1(500 ohm, 1 Kohm, & 2K2 ohm ) are also mounted on front panel.